Where is the heat stored, and how is it kept in?
Heat is stored inside the Heat Cell: a steel vessel containing the solid aluminium-composite storage blocks, the embedded heating elements and the embedded steam coils, all enclosed by a double-walled vacuum-insulated cover.
The cover works on the same principle as a vacuum flask. The vacuum prevents heat loss by conduction and convection, and a radiant barrier reduces loss by radiation. With the core at 500°C, the outside surface of the cover stays only a few degrees above ambient temperature. Standing heat loss is 8 kW per Heat Cell, about 3.6% of a full charge per day, so a full store still holds most of its useful heat after several days.
All valves, actuators and serviceable components are located outside the hot core, where they can be inspected and maintained without opening the vessel. There are no moving parts inside the thermal store itself, which means there is nothing in the hot zone to wear out, lubricate or replace over the 20-year life. The Heat Cell is weatherproof and designed to be installed outdoors, so it can be retrofitted to an existing site without building a shelter or plant room for it.